How To Set Exercise On Generac Generator
Support For Your 0062440
Questions? Telephone call The states! 888-GENERAC
Overview
- Max. Cont. Power (LP): 20 kW
- Max. Cont. Power (NG): 18 kW
- Max. Cont. Amps (LP/NG): 83.3/75
- Master Line Circuit Breaker: 100 amp
- Bombardment Blazon: Group 26R, 12V, 525 CCA
- Oil Type: Check chart in transmission
- Oil Chapters: 1.9 quarts
- Oil Filter P/N: 070185F
- Air Filter P/N: 0J8478S
- NG Consumption-l% : 205 ft3/60 minutes
- NG Consumption-100% : 308 ft3/hr
- LP Consumption-50% : 69 ft3/60 minutes
- LP Consumption-100% : 106 ft3/hr
- NG Fuel Pressure Req.: five-vii in. water cavalcade
- LP Fuel Pressure Req.: x-12 in. water column
Manuals
FAQs
These FAQs might not directly use to your product. Always consult your user manual for exact operating and maintenance solutions.
Functioning
-
How do I open an air-cooled home standby generator?
Air-cooled home standby generators manufactured in 2008 or later require a fundamental to unlock its two locks before opening the hat. The unit of measurement is locked when information technology is shipped. To open the hat for the first time. the customer volition need to use heavy force per unit area on the lid to a higher place each lock while turning the fundamental at the same time.
-
How long can I continuously operate my home standby generator?
During an outage, nosotros recommend the generator be shut down every 24 hours to inspect the air filter and oil level. Let the engine absurd for approximately xv minutes to become an accurate reading on the dipstick. A consummate oil modify will need to be performed after every 200 hours of functioning for air-cooled units, or every 100 hours of operation for liquid-cooled units.
General Information
-
Are extended warranties bachelor for my home standby generator?
Extended warranties are available for our dwelling standby and commercial generators, (this does not include the CorePower Serial,EcoGen, portables or power washers.) Information technology must be purchased from an authorized sales/service dealer within the commencement yr of ownership.Talk with your dealer for more details.
-
What constitutes a voided warranty?
The following installations will void the warranty on an automatic standby generator: *Generators used where no utility power is present(east.thousand.,hunting cabins) *Generators used to modify backup battery systems for alternative energy sources (this does non include the EcoGen series). *Improper installations (clearance requirements, wiring.etc). *Modifcattions to the original design (extending the exhaust,etc.) *Indoor installations.
-
If I have my contractor replace a part, how will they get reimbursed?
Any service work performed by someone Generac has not authorized to perform warranty work cannot be claimed and volition not be covered under warranty. This includes any repair piece of work performed by an electrical contractor who is not affiliated with a service dealership. Regular maintenance, such equally changing the oil and filter, can exist done by anyone and is not covered nether the warranty.
-
What is an automated standby generator?
An automated standby generator is a back-up electrical system that operates whether you are home or away. Within seconds of an outage. it automatically supplies power directly to your abode's electric circuit breaker box. After utility power returns, the generator shuts itself off and waits for the next outage. It operates on natural gas or liquid propane gas and sits outside, only like a central air-conditioning unit.
Maintenace & oil information
-
Tin can I perfom maintenance myself?
Ever check your owner's manual to confirm specific maintenance intervals for your item model. Anyone tin can perform maintenance, but we recommend a sale or service dealer equally some aspects are very technical. Dealers can too brand sure everything eles is in order. Most units with an OHVI engine volition require maintenance every two years, or after 200 hours of use. The CorePower Serise(OHV engine) requires maintenance every twelvemonth, or later on 100 hours of apply. The EcoGen (6kW) requires maintenance after 500 hours of utilise. Liquid-cooled units require maintenance every year, or afterwards 100 hours of use.
-
Are in that location maintenance kits available for my dwelling house standby generator?
Maintenance kits and parts can exist purchased from any sales or service dealer. through our office distributors (GPCs) or online at ordertree.com. Only Generac-make maintenance parts should be used; we don't recommend and don't accept cantankerous-reference numbers for other brands like Fram or Napa.
-
What kind of oil and coolant exercise I need to apply ?
Air-cooled units will come with some SAE 30wt. oil from the factory. You volition want to check the level and add more if necessary during the installation. Liquid-cooled units are shipped with oil and coolant. No additional oil needs to be added during installation.
-
What is the recommended oil to utilise?
Ever check the manual for each specific model as oil recommendations change depending on the model. Our oil recommendations are based on climate or temperature. For areas with seasons, synthetic 5W-30 can be used year-around, but is not recommended in very cold temperatures.
-
Why use synthetic oil?
Oil recommendations are based on temperature, but synthetic oil is a good option because it doesn't degrade or "sludge" like standard oil. It besides has better lubrication properties and stands upwards ameliorate to high temperatures in the engine.
-
What is the break-in period for my habitation standby generator?
Current model air-cooled units do non crave a pause-in menses. They can be switched to synthetic or any weight oil immediately. Older air-cooled product required an eight-hour break-in period. The unit should run for eight hours (exercise or while powering the firm) before switching to constructed. Delight check your owner's transmission to see if this was required for the item unit of measurement.
Troubleshooting
-
What'south the all-time fashion to troubleshoot my domicile standby generator?
We are limited equally to the troubleshooting we are able to do without potentially damaging the production or voiding the warranty of the product (if applicable). Contact your local dealer for service if issues persist.
-
How do I observe an authorized service dealer?
Authorized service dealers can be located on our website.
Installation
-
What are the installation clearance requirements for standby generators?
All standby generator clearance requierments are dicated by the National Burn Protection Association (NFPA) lawmaking 37. They must exist a minmum of five feet from whatever openings in the walls (i.e., doors,windows, sealed windows. etc.) The minmum distance from the top of the unit is besides five anxiety. Our air-cooled home standby generators crave a minmum of 18 inches of clearance from the backside of the generator (where the electric and gas inlets are located) and a minmum of 36 inches of clearance on all other sides (intake ,frazzle and from forepart side). This does not apply to the 7kW CorePower TM Series. Generac liquid-cooled home standby generators, equally well equally CorePower Series and portable units, crave a minimum of 36 inches of clearance from any non-combustible surfaces (i.e., concrete, brick, etc.) and a minimum of threescore inches from any flammable surfaces (i.east., vinyl siding , wood. etc.).
-
How do I activate my home standby generator?
Products with a digital control panel manufactured in 2010 or later require an activation code before the unit can be operated in automatic mode.(The unit of measurement will only run in transmission mode if non activated) to get the activation code. Register the product on either generac.com or activategen.com. The confirmation page (final page of the registration ) volition bear witness the five-digit activation code at the height of the screen. For any questions or bug, calls tin be transferred to our activation line (x-2832) or (888) 922-8482 (this applies to models manufactuerd in 2010 or later).
-
How do I size the right gas line for my home standby generator installation?
We are not able to size the gas line for you lot. However, nosotros are able to give the fuel consumption and required water column which will help the gas installers to provide the correct sizes needed for installation. These are unique to each model, consult your owner'south transmission for details. Because there are so many factors that can bear upon gas pressure, such as having a line that is not defended and the distance that the line is run, your installation will require an on-site inspection and recommendation by a gas professional.
-
How exercise I set the exercise time?
For all units, 6 kW and viii-20 kW, the exercise fourth dimension tin be set from the control board on the "edit" screen. But select the date and time using the up and down arrow keys. The generator time and exercise time are in military time, so if you would like the generator to excerise at 1 PM set the practice for 1300 hours. The CorePower TM Serial/analog command boards tin be set by pressing and holding the "set exercise" button for 10 seconds or until the generator starts. The unit of measurement will exercise weekly on that mean solar day and time each week. To reset the practise, disconnect the battery and press / hold the button once more at the desired day/time.
-
How do I summate fuel consumption conversion?
To size a gas line for a generator, virtually gas companies/ plumbers will need 2 pieces of data -h2o column and BTU's. All h2o cavalcade/ fuel-force per unit area and BTU information is available in your owner's transmission.
Accessories
Reviews
Own this model? Please write a review! Click the push below, so find your model pictured in the list shown and click the 'Write a Review' Link.